The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Photo of Mattias Ohlsson

Mattias Ohlsson

Professor

Photo of Mattias Ohlsson

Toward personal eHealth in cardiology. Results from the EPI-MEDICS telemedicine project

Author

  • Paul Rubel
  • Jocelyne Fayn
  • Giandomenico Nollo
  • Deodato Assanelli
  • Bo Li
  • Lioara Restier
  • Stefano Adami
  • Sebastien Arod
  • Hussein Atoui
  • Mattias Ohlsson
  • Lucas Simon-Chautemps
  • David Telisson
  • Cesare Malossi
  • Gian-Luca Ziliani
  • Alfredo Galassi
  • Lars Edenbrandt
  • Philippe Chevalier

Summary, in English

The purpose of this study was to develop a method based on artificial neural networks for interpretation of captopril renography tests for the detection of renovascular hypertension caused by renal artery stenosis and to assess the value of different measurements from the test. A total of 250 99mTc-MAG3 captopril renography tests were used in the study. The material was collected from two different patient groups. One group consisted of 101 patients who also had undergone a renal angiography. The angiographies, which were used as gold standard, showed a significant renal artery stenosis in 53 of the 101 cases. The second group consisted of 149 patients, who's captopril renography tests all were interpreted as not compatible with significant renal artery stenosis by an experienced nuclear medicine physician. Artificial neural networks were trained for the diagnosis of renal artery stenosis using eight measures from each renogram. The neural network was then evaluated in separate test groups using an eightfold cross validation procedure. The performance of the neural networks, measured as the area under the receiver operating characteristic curve, was 0.93. The sensitivity was 91% at a specificity of 90%. The lowest performance was found for the network trained without use of a parenchymal transit measure, indicating the importance of this feature. Artificial neural networks can be trained to interpret captopril renography tests for detection of renovascular hypertension caused by renal artery stenosis. The result almost equals that of human experts shown in previous studies.

Department/s

  • Computational Biology and Biological Physics - Undergoing reorganization
  • Nuclear medicine, Malmö

Publishing year

2005

Language

English

Pages

100-106

Publication/Series

[Host publication title missing]

Volume

38

Issue

4

Document type

Conference paper

Publisher

Elsevier

Topic

  • Cardiac and Cardiovascular Systems

Conference name

Annual ISCE Conference

Conference date

0001-01-02

Status

Published

Research group

  • Nuclear medicine, Malmö

ISBN/ISSN/Other

  • ISSN: 0022-0736
  • ISSN: 1532-8430